Aging housing project
Make no. : XT120010
1.system composition:
The system consists of insulated building, heat fan, in and out of the wind pipe and security alarm system, dedicated to electronic instrument product environment temperature aging test.
, by industrial hot air blower for cyclic heating aging room;
, by which has the function of PID intelligent instrument to control the temperature;
2, the basic parameters:
Temperature range: normal temperature 55 ~ 60 ℃, the highest temperature 75 ℃
• temperature deviation: + / - 1 ℃
Heating time: 20 ~ 60 ℃, about 30 minutes (light)
Control mode: air forced circulation temperature adjustment methods
Heating method: electric heating circulation wind
, temperature measurement sensor, thermocouple, overheating protection device
• input power: 380 vac, three-phase five line
3, aging room size (can be determined according to user requirements) :
Internal size: 2880 * 2000 * 2000 mm3 (length x width x height)
External size: 3030 mm * 2150 mm * 2075 mm3 (length x width x height)
|