The relief valve discharge pressure tester XT72 series
This detector is dedicated to setting pressure of safety valve (also called "opening pressure" or "release stress"), can also test the burst pressure containers of all kinds (also called "maximum pressure"), through the setting of the relief valve discharge pressure upper limit and lower limit, can detect and display the relief valve discharge interval (low, normal and high) and the maximum pressure before discharge, automatically shut down after the relief valve discharge air (energy-saving, environmental protection). The using my company's new XT0706 chassis series.
According to the requirements of customers, our company and on the basis of original increased the function of remote control, the operator only needs to near the relief valve by the remote control can operate the whole detection process.
Main performance:
l
The test pressure: 0 ~ 900.0 KPa;
L damage pressure: 2.0 MPa;
L digital display: 0 ~ 999.9
L minimum value: 0.1 KPa;
L precision level: 0.25 on the Richter scale;
L with tracheal: 6 x 4 pu tube
Or 8 x 5 pu tube;
L control mode: automatically shut off gas source;
L working power supply: AC 220 v;
L the machine power consumption: less than 35 va;
L product appearance: see the picture on the right
L panel size: 440 x 230 x 230 high wide was deep
L site operation instructions
1. The site must be equipped with compressed air, the output pressure is slightly larger than testing pressure (pressure reducing valve by adjusting the air compressor implementation);
2. Connect the power supply and ventilation way, set up safety normal discharge upper limit and lower limit, adjust the pressure regulating valve inlet pressure slightly higher than the upper limit.
3. Press the start button, gas path through, as the measured pressure relief valve, safety valve to be tested according to the discharge pressure can be divided into three kinds of circumstances, at the same time program controller always stay in front of the relief valve discharge "maximum pressure", the next time pressure automatically remove the "maximum pressure";
lXT72Complete valve tester manual(CH) File Size:82.45KB Click to download
|