XT71 series fully automatic pressure switch tester
Make no. : XT710000
The detector is dedicated to the pressure switch (pressure switch) pressure detection, by setting air pressure switch action pressure upper limit and lower limit, can detect and display the pressure switch action range (low, normal and high) and the maximum pressure before action, action automatically shut down after air pressure switch. The using my company's new XT7 chassis series.
According to the requirements of customers, our company and on the basis of original increased the function of remote control, the operator only needs to near the air pressure switch by remote control can operate the whole detection process.
Main performance:
L test pressure: 900.0 KPa;
L damage pressure: 2.0 MPa;
L digital display: 0 ~ 999.9
L minimum value: 0.1 KPa;
L precision level: 0.25 on the Richter scale;
L with tracheal: 6 x 4 pu tube
Or 8 x 5 pu tube;
L control mode: automatically shut off gas source;
L working power supply: AC 220 v;
L the machine power consumption: less than 35 va;
L product appearance: see the picture on the right
L panel size: 440 x 230 x 230 high wide was deep
L site operation instructions
1. The site must be equipped with compressed air, the output pressure is slightly larger than testing pressure (pressure reducing valve by adjusting the air compressor implementation);
2. Connect the power supply and ventilation way, set up safety normal action of upper and lower limit, adjust the pressure regulating valve inlet pressure slightly higher than the upper limit.
3. Press the start button, gas path connected, for the measured pressure switch, pressure measured pressure switch will be according to the operating pressure is divided into three kinds of situations, and the program controller keeps pressure switch action before the "maximum pressure", the next time pressure automatically remove the "maximum pressure";
L the blue light is lit, said pressure switch action when the pressure is lower than the lower limit value, unqualified;
L green indicator; Said pressure switch action when pressure is higher than the lower limit value and below the upper limit value, qualified;
L red indicator; Said on the pressure switch pressure is higher than the upper limit value and pressure switch is not action, unqualified (in order to ensure the safety of the operator and the pressure switch, the system will automatically discharge pressure source).
XT71 Automatic pressure switch tester(CH) File Size:135KB Click to download
|